Introduction: Microrobots hold enormous potential in the biomedical field (targeted drug delivery, disease diagnosis and minimally invasive surgery), but clinical translation faces two major bottlenecks. First, conventional fabrication methods struggle to achieve both scalability and high precision: conventional two-photon lithography (TPP) requires mixing magnetic nanoparticles into the resin, which easily reduces resin transparency (affecting laser polymerization efficiency) and causes particle agglomeration (reducing performance uniformity), while subsequent magnetic coating processes are costly and the amount of magnetic material is limited. Second, existing imaging techniques (such as MRI, ultrasound and OCT) cannot achieve non-invasive, precise tracking of microrobots in deep biological tissue: MRI has poor compatibility with magnetic actuation, ultrasound resolution is low, and OCT penetrates only a few millimeters, making it hard to meet clinical needs. To solve these problems, in August 2025 the research team led by Jinxing Li at Michigan State University published "TriMag Microrobots:3D-Printed Microrobots for Magnetic Actuation,Imaging,and Hyperthermia" in the journal ADVANCED MATERIALS, proposing an innovative approach: combining two-photon lithography (TPP) 3D printing with in situ chemical reactions, using biocompatible PEG-DA/PETA hydrogel as the scaffold, first printing a mixture of Fe²⁺, Fe³⁺ and Co²⁺ metal ions with the photosensitive hydrogel, and then triggering in situ reactions with NH₄Cl or NaOH to generate Fe₃O₄ nanoparticles (improving MPI contrast and magnetic driving force) and CoFe₂O₄ nanoparticles (enhancing magnetic hyperthermia efficiency). The result is the TriMag microrobot, which integrates magnetic actuation, MPI imaging and magnetic hyperthermia. At the same time, MPI technology (free from biological tissue interference, with submillimeter resolution) enables real-time tracking of robots in deep tissue, providing an integrated solution for the clinical application of microrobots.
Abstract: Microrobots have enormous potential in biomedical applications, including drug delivery, disease diagnosis and minimally invasive surgery. However, two key challenges hinder their clinical translation: achieving scalable, high-precision fabrication, and achieving non-invasive imaging and tracking within deep biological tissue. Magnetic particle imaging (MPI), a frontier imaging technique that detects the magnetization of nanoparticles, can visualize superparamagnetic nanoparticles (SPIONs) with submillimeter resolution without interference from biological tissue, thereby effectively addressing these challenges. This makes MPI an ideal tool for tracking magnetic microrobots in deep tissue environments. This study presents the "TriMag" microrobot: a 3D-printed microrobot that integrates three magnetic functions — magnetic actuation, magnetic particle imaging and magnetic hyperthermia. The TriMag microrobot is fabricated by an innovative method that combines two-photon lithography for 3D printing biocompatible hydrogel structures with in situ chemical reactions, embedding two types of nanoparticles in the hydrogel scaffold: Fe₃O₄ nanoparticles for good MPI contrast and CoFe₂O₄ nanoparticles for efficient magnetothermal heating. This approach enables scalable, high-precision fabrication of helical magnetic hydrogel microrobots. Through the synergy of Fe₃O₄ and CoFe₂O₄ nanoparticles, the resulting TriMag microrobot exhibits the following capabilities: efficient magnetic actuation for controlled motion; precise imaging and tracking by MPI in biological fluids and organs (including porcine eyes and mouse stomachs); and magnetothermal heating for tumor ablation in mouse models. By integrating these functions, this fabrication and imaging approach provides a robust platform for the non-invasive monitoring and manipulation of microrobots, with the potential for transformative applications in medical therapy and biological research.
Research innovations
Innovation in fabrication method: overcoming the bottlenecks of conventional 3D printing
Conventional two-photon lithography (TPP) for fabricating magnetic microrobots requires mixing nanoparticles into the resin, which easily reduces resin transparency (affecting laser polymerization efficiency) and causes nanoparticle agglomeration (reducing performance uniformity). This study instead adopts a "metal ion precursor + in situ reaction" strategy: Fe²⁺, Fe³⁺ and Co²⁺ ions are mixed with the photosensitive hydrogel and printed, and after printing NH₄Cl/NaOH triggers in situ reactions that generate Fe₃O₄ and CoFe₂O₄ nanoparticles. This preserves resin transparency (without affecting TPP precision), achieves uniform nanoparticle distribution, and also supports scalable fabrication (as shown by SEM images of helical arrays).
Innovation in functional integration: the first realization of "actuation-imaging-therapy" triple synergy
Existing magnetic microrobots mostly offer only a single function (for example, actuation only or imaging only). Through the coordinated design of Fe₃O₄ and CoFe₂O₄, this study integrates three core functions for the first time: Fe₃O₄ is responsible for high-contrast MPI imaging and for generating magnetic actuation torque, while CoFe₂O₄ is responsible for efficient magnetic hyperthermia; together they improve actuation stability and break through the limitation of "fragmented functionality".
Innovation in imaging technology: MPI overcomes the challenge of deep tissue tracking
Compared with MRI (poor compatibility with magnetic actuation), ultrasound (low resolution) and OCT (penetration depth of only a few millimeters), MPI detects the magnetization of superparamagnetic nanoparticles and thus enables deep imaging with submillimeter resolution and no interference from biological tissue. This study verifies that MPI can precisely locate robots in the porcine vitreous body (ophthalmic applications) and the mouse stomach (gastrointestinal applications), and can also determine the spatial pose of a robot through multi-view imaging, providing a basis for closed-loop control.
Innovation in biocompatibility and practicality:
The robots use a degradable PEG-DA/PETA hydrogel (which degrades slowly in body fluids such as PBS and serum), and hemolysis experiments show a hemolysis rate of <5%, demonstrating biosafety. The robots are designed with a helical structure (mimicking the flagellar motion of E. coli), enabling efficient propulsion in low-Reynolds-number environments such as body fluids, and the speed and direction of motion can be controlled by adjusting the magnetic field frequency/amplitude (with optimal speed at 50Hz, for example).
Experimental validation shows:
The robot can be precisely actuated by a 3-axis Helmholtz coil system (for example, a single robot writing "MBOT" and a swarm moving in a coordinated manner); with MPI, real-time tracking in deep tissue (submillimeter resolution) was achieved in a porcine brain phantom, the porcine vitreous body and the mouse stomach; in a mouse tumor model, the robot reached the tumor region under targeting, and an alternating magnetic field triggered magnetic hyperthermia (raising the local temperature to 43℃), achieving tumor ablation without obvious side effects. This study provides an integrated solution for the non-invasive monitoring and manipulation of microrobots.

Figure 1: Fabrication and functions of the TriMag microrobot
Figure 1a: Schematic of the TPP fabrication workflow
On the left is the two-photon polymerization (TPP) process: PEG-DA/PETA serves as the photosensitive hydrogel, Fe²⁺, Fe³⁺ and Co²⁺ ion precursors are added, and laser focusing achieves 3D curing of the hydrogel; on the right is the in situ chemical reaction: after printing, OH⁻ is added (such as NH₄Cl/NaOH), Fe²⁺/Fe³⁺ react with OH⁻ to form Fe₃O₄ (reaction: Fe²⁺+2Fe³⁺+8OH⁻→Fe₃O₄+4H₂O), and Co²⁺/Fe³⁺ react with OH⁻ to form CoFe₂O₄ (reaction: Co²⁺+2Fe³⁺+8OH⁻→CoFe₂O₄+4H₂O), ultimately forming a hydrogel robot embedded with both types of nanoparticles.
This workflow solves the problem in conventional TPP where nanoparticles affect resin transparency, realizing integrated "printing-functionalization".
Figure 1b: Schematic of the triple magnetic functions
The three core functions of the robot are clearly labeled: ① magnetic actuation (an external magnetic field controls robot motion); ② MPI imaging (an MPI scanner detects the magnetization signal of Fe₃O₄ for localization and tracking); ③ magnetic hyperthermia (an alternating magnetic field triggers heat generation in CoFe₂O₄ for tumor ablation). All three are realized through the synergy of the two nanoparticles, with no functional conflict.
Figure 1c: SEM images (helical structure and array)
Two views are included: top and tilted views of a single helical robot at the top (scale bar 10μm), and a robot array at the bottom (scale bar 100μm). The images show smooth hydrogel surfaces and uniform dimensions (helix length about 100μm, suitable for in vivo applications), demonstrating the high precision and scalable fabrication capability of TPP (the array shows no obvious structural defects).

Figure 2: Morphology and elemental analysis of the TriMag microrobot
Figure 2a: Visualization experiment of the in situ reaction
Shows that after 10%NaOH is added to a block of PEG-DA/PETA hydrogel fiber, its color gradually changes from transparent to "iron-colored" (time points: 0→1→5→25→30min, scale bar 1cm), directly demonstrating that Fe/Co ions react with OH⁻ to form magnetic nanoparticles; the magnet attraction experiment on the right further confirms that the hydrogel is magnetic (it can be attracted by a magnet after the reaction).
Figure 2b: Schematic of nanoparticles embedded in the hydrogel
A simplified illustration of the porous network structure of the hydrogel: Fe₃O₄ and CoFe₂O₄ nanoparticles both attach to the hydrogel surface and are enclosed within the network, explaining the structural basis of the robot's magnetic functions.
Figure 2c: SEM images of the bulk hydrogel
Scale bars are 100μm (left) and 20μm (right), showing a porous internal structure (pore size suitable for nanoparticle embedding) with nanoparticles uniformly distributed on the pore walls and surface (no obvious agglomeration), demonstrating that the in situ reaction can control nanoparticle dispersion.
Figure 2d: Structural schematic of the helical robot
Fe₃O₄ (red) and CoFe₂O₄ (blue) nanoparticles distributed on the robot surface are labeled, clarifying the regions where the two particles act synergistically.
Figure 2e-f: SEM and EDX mapping images of the robot surface
The SEM image (scale bar 50μm) shows a rough robot surface (due to attached nanoparticles); the EDX maps label the distribution of C, O, Fe and Co, demonstrating that Fe and Co uniformly cover the robot surface (without local enrichment) and verifying the uniformity of the in situ reaction.
Figure 2g: Quantitative EDX elemental analysis
The bar chart shows the characteristic peak intensities of Fe and Co, further confirming the presence and ratio of the two elements (matching the precursor ion concentration) and ruling out interference from impurities.

Figure 3: Magnetic actuation system and performance of the TriMag microrobot
Figure 3a: Schematic of the magnetic actuation system
Shows a 3-axis Helmholtz coil (providing a rotating magnetic field), a liquid container (simulating the in vivo environment) and an objective lens (imaging and tracking), forming an integrated "actuation-observation" system; the robot is labeled rotating and propelling under the magnetic field in the liquid, explaining the working logic of the actuation system.
Figure 3b: Numerical model of the robot
A geometric model of the helical robot is established (length 100μm, helix angle 45°) for subsequent computational fluid dynamics (CFD) simulations.
Figure 3c: CFD simulation results (50Hz actuation frequency)
The time series (0→0.04→0.08→0.13→0.17→0.21s) shows the robot's trajectory in the liquid; the simulation matches the laminar flow characteristics of a low-Reynolds-number environment (similar to body fluids), proving that the helical structure converts rotational motion into linear propulsion (mimicking bacterial flagella).
Figure 3d: Relationship between helix angle and misalignment angle
The horizontal axis is the helix angle (°) and the vertical axis the misalignment angle (the angle between the magnetization direction and the robot axis). The results show that when the helix angle is 45°, the misalignment angle is smallest (close to 0), indicating that this angle reduces the directional deviation between the magnetic field and the robot and maximizes propulsion efficiency, providing a basis for optimizing the robot structure.
Figure 3e: Frequency-velocity relationship
Compares the motion speed of three robots (Fe₃O₄ only, CoFe₂O₄ only, and Fe₃O₄+CoFe₂O₄) at different magnetic field frequencies (unit: body lengths per second). The Fe₃O₄+CoFe₂O₄ group is the fastest (about 1.7 body lengths/s at 50Hz), while the CoFe₂O₄-only group is the slowest (due to low saturation magnetization), proving that the synergy of the two nanoparticles enhances actuation performance.
Figure 3f: Snapshots of the actuation process
Optical microscope images (scale bar 50μm) capture the robot's helical propulsion in the liquid; the rotation of the robot tail generating propulsion is visible, consistent with the CFD simulation results and verifying the feasibility of the actuation principle.
Figure 3g: Trajectory control experiments
On the left is the trajectory of a single robot writing "MBOT" (scale bar 200μm); on the right are the coordinated swarm trajectories of 3 robots, proving that the robots can be precisely controlled individually and as a group by adjusting magnetic field parameters (frequency, amplitude and direction), laying the groundwork for targeted delivery.

Figure 4: MPI characterization of the TriMag microrobot
Figure 4a: Schematic of the MPI system principle
Shows the core components of MPI: the selection field coil (generating the field-free line), the drive field coil (applying an alternating magnetic field) and the receive coil (detecting the magnetization signal of nanoparticles). When the field-free line sweeps across the robot, changes in the magnetization of Fe₃O₄ induce a voltage signal in the receive coil, producing an image; this explains why MPI has no background interference.
Figure 4b: Hysteresis loops of different materials
Compares the hysteresis loops of four materials (pure hydrogel, Fe₃O₄ hydrogel, CoFe₂O₄ hydrogel and Fe₃O₄+CoFe₂O₄ hydrogel) at room temperature (x-axis: magnetic field strength in Oe; y-axis: magnetization). The Fe₃O₄+CoFe₂O₄ group is superparamagnetic (an almost closed loop with low remanence) and has high magnetic susceptibility near zero field (suitable for MPI imaging); the "small loop" in its hysteresis curve indicates a large bulk anisotropy constant, giving better magnetic hyperthermia performance than pure Fe₃O₄, confirming the synergistic advantage of the two nanoparticles.
Figure 4c: MPI imaging experimental setup
The four materials were formed into spherical hydrogels 1mm in diameter and fixed in a 35mm petri dish (scale bar 10mm), then imaged with an MPI scanner to directly compare the MPI signal intensity of different materials.
Figure 4d: Quantitative MPI signal intensity
The horizontal axis shows the material type (pure gel, CoFe₂O₄, Fe₃O₄, Fe₃O₄+CoFe₂O₄ and the commercial Fe₃O₄ reagent VivoTrax) and the vertical axis the signal intensity. The Fe₃O₄ group and the Fe₃O₄+CoFe₂O₄ group show signal intensities close to VivoTrax (significantly higher than the CoFe₂O₄ group and pure gel), proving that Fe₃O₄ is the main contributor to MPI imaging and that the addition of CoFe₂O₄ does not affect the MPI signal.
Figure 4e: Statistical analysis of MPI sensitivity
The bar chart (sample size n=3, error bars mean±SD) further verifies the results in Figure 4d: the sensitivity of the Fe₃O₄+CoFe₂O₄ group is not significantly different from that of the Fe₃O₄ group (p>0.05), ruling out interference of CoFe₂O₄ with MPI performance.
Figure 4f: Multi-view MPI imaging of a single robot
Shows MPI images of the robot from three views — (1,0,0), (1,1,0) and (1,1,1) (scale bar 500μm): the (1,1,0) plane gives the strongest signal (corresponding to the longitudinal cross-section of the robot), the (1,0,0) plane shows a blurred dot, and the (1,1,1) plane reveals a "magnetized head + helical tail". The results prove that MPI can identify the spatial pose of the robot, providing directional feedback for closed-loop control.
Figure 4g: MPI resolution validation experiment
Two robots are brought gradually closer along the radial direction (distances: 1.535→0.781→0.243mm); MPI images show that the two robots can be distinguished when the distance is ≥0.243mm, while the images merge when it is <0.243mm. This demonstrates that the spatial resolution of MPI reaches the submillimeter level and that magnetic interaction between robots does not affect imaging accuracy, providing a basis for swarm robot tracking.

Figure 5: MPI imaging validation in biological tissue
Figure 5a: Schematic of robot motion in a confined in vivo environment
A simplified illustration of robot motion in complex in vivo environments such as blood vessels and organs, highlighting the tracking advantage of MPI under "no tissue interference".
Figure 5b: Porcine brain tissue phantom setup
A vessel phantom filled with fresh porcine brain tissue was constructed (scale bar 10mm) to simulate a deep tissue environment; the robot was driven by an alternating magnetic field plus a strong magnetic gradient to verify its mobility in dense tissue.
Figure 5c: Imaging of the robot at 7 positions in the phantom
Time-series MPI images show the robot's trajectory in the phantom (7 marked points), proving that the robot can propel through porcine brain tissue and that MPI can locate it clearly.
Figure 5d: MPI signal intensity versus position
The horizontal axis is the position within the phantom (mm) and the vertical axis the MPI signal intensity. The peaks correspond to the center-of-mass positions of the robot, matching the marked points in Figure 5c one to one and verifying the accuracy of MPI localization.
Figure 5e: Schematic of robot actuation in the porcine vitreous body
The anatomical structures of the porcine eye (vitreous body, retina, choroid and sclera) are labeled; the robot enters by intravitreal injection and is intended to advance toward the fundus (a key region for treating diseases such as diabetic retinopathy).
Figure 5f: CT-MPI fused imaging of the robot in the porcine eye
The time series (0→10→20→30min) shows the robot migrating from near the eye wall toward the fundus (scale bar 5mm); CT provides the anatomical background of the eye while MPI precisely marks the robot position, proving that the robot can be precisely actuated in the vitreous body, offering possibilities for minimally invasive ophthalmic treatment.
Figure 5g: Schematic of the mouse stomach experiment
The robot enters the mouse stomach by oral gavage; with 10% barium sulfate (BaSO₄) + 0.5% mannitol as the CT contrast agent, fused imaging of CT (showing stomach anatomy) and MPI (showing the robot) is achieved.
Figure 5h: "C"-shaped trajectory of the robot in the mouse stomach
CT-MPI fused images (scale bar 10mm) show the robot moving along a "C"-shaped trajectory in the stomach (simulating a clinical gastric intervention path), proving that the robot can achieve controllable motion inside a living organ and that MPI can track it in real time.

Figure 6: Magnetic hyperthermia experiments with the TriMag microrobot
Figure 6a: Schematic of the magnetic hyperthermia experimental setup
Shows a custom magnetic hyperthermia generator (producing an alternating magnetic field of 150-300kHz), hydrogel samples and a fiber-optic temperature sensor (TS2-02), used to measure the heating efficiency of different materials (scale bar 15mm).
Figure 6b-c: Temperature change curves at different frequencies
The horizontal axis is time (min) and the vertical axis temperature (℃), comparing the heating of three materials (Fe₃O₄, CoFe₂O₄, Fe₃O₄+CoFe₂O₄) under alternating magnetic fields of 150kHz (Figure 6b) and 300kHz (Figure 6c). The Fe₃O₄+CoFe₂O₄ group heats fastest, reaching 41℃ within 10min at 150kHz (the threshold temperature for tumor ablation), with a further increase in heating rate at 300kHz, proving that the synergy of the two nanoparticles enhances magnetic hyperthermia efficiency.
Figure 6d: Schematic of the robot design for tumor ablation
After injection around the tumor, the robot is driven into the tumor stroma by a rotating magnetic field (2Hz), and then a 150kHz alternating magnetic field is applied to trigger local heating for tumor ablation (avoiding damage to surrounding healthy tissue).
Figure 6e-f: 2D/3D CT-MPI imaging of the robot in mouse tumors
Figure 6e (2D, scale bar 10mm) shows the robot migrating from the injection site to the tumor margin within 30min (tracked every 10min); Figure 6f (3D) clearly labels the spatial relationship between the robot and the tumor, proving that the robot can precisely reach the tumor region.
Figure 6g: Thermal images of the magnetic hyperthermia process
The time series (0→5→10→15min) thermal images show the tumor region warming from 35.6℃ to 43℃ (scale bar 15mm); 43℃ is an effective tumor ablation temperature (below the 45℃ damage threshold for healthy tissue), and the temperature distribution is concentrated (without obvious spread), demonstrating the targeting of magnetic hyperthermia.
Figure 6h: IVIS fluorescence imaging to assess tumor response
In luc2-labeled 4T1 breast cancer mouse models, IVIS fluorescence imaging was performed 0-4 days after treatment (scale bar 15mm): the tumor fluorescence signal did not decrease in the untreated group (PBS injection) or the robot-only injection group, whereas it decreased significantly in the magnetic hyperthermia group, proving that the tumor tissue was effectively ablated.
Figure 6i: Workflow of in vivo tumor treatment
The workflow is: ① tumor cells were inoculated 7 days earlier (1×10⁶ 4T1 cells); ② the robot was injected around the tumor; ③ the robot was driven to the tumor site by a magnetic field; ④ an alternating magnetic field triggered magnetic hyperthermia; ⑤ body weight, tumor volume and fluorescence intensity were monitored over 4 days. The results show that treated mice maintained stable body weight (no toxicity) and showed significantly reduced tumor volume, verifying the safety and efficacy of the treatment.
Addressing the pain points of "scalable high-precision fabrication" and "non-invasive imaging and tracking in deep tissue" in the clinical translation of microrobots, the team proposed an innovative approach of "two-photon lithography (TPP) 3D printing + in situ chemical reaction". Using biocompatible PEG-DA/PETA hydrogel as the scaffold, Fe₃O₄ (ensuring MPI imaging contrast and magnetic actuation) and CoFe₂O₄ (enhancing magnetic hyperthermia) nanoparticles were embedded in situ to fabricate the TriMag microrobot integrating magnetic actuation, MPI imaging and magnetic hyperthermia. Experiments verified that it can be precisely actuated by a 3-axis Helmholtz coil, tracked in deep environments such as the porcine eye and the mouse stomach via MPI, and can target and ablate tumors in a mouse model with good biosafety, providing an integrated platform for the clinical translation of microrobots.
Source:L. Xing, Y. Cai, Y. Zhang, et al. “ TriMag Microrobots: 3D-Printed Microrobots for Magnetic Actuation, Imaging, and Hyperthermia.” Adv. Mater. (2025): e19708. https://doi.org/10.1002/adma.202419708
Article URL:TriMag Microrobots: 3D‐Printed Microrobots for Magnetic Actuation, Imaging, and Hyperthermia - Xing - Advanced Materials - Wiley Online Library